pany to ensure compliance with their
regulations.
The appliance socket switch should be
outside the cabinet but within 2 m of
the appliance to make it accessible to
switch off the appliance in case of an
emergency.
To protect the hands, wear gloves
when lifting the oven into its housing.
HOUSE CIRCUIT
Earth leakage and continuity tests
must be carried out before the ap-
pliance is connected to the mains
supply and re-checked after fit-
ting.
GETTING THINGS READY
CHOICE OF ELECTRICAL
CONNECTION
By connecting to a cooker point (hav-
ing a double pole isolating switch with
at least 3 mm contact separation in all
poles and neutral) and protected with
a fuse or miniature circuit breaker at
your mains fuse box.
It is good practice to :
Fit an Earth Leakage Circuit
Breaker to your house wiring.
Wire your appliance to the latest
IEE regulations.
Electrical Installation
Enquiries regarding the installation of
the cooker point, if required, should be
made to your Regional Electricity Com-
The appliance should be operated
using at least 6 mm² twin core and
earth PVC insulated multicore cable.